Opera Carbon Monoxide replacement Sensor Modules

Replacement Sensor Modules

Ammonia NH3Ammonia – NH3 – Model 5504 Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated electro-chemical type sensor expected life 1 to 3 years (varies with environments conditions)

Oxygen depletion O2 – Model 5523  for alarms on dropping levels of oxygen (for rising levels see model 5522) Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated expected life 2 years fuel cell type sensor

model 5502-CoCarbon Monoxide – CO – Model 5502  (0-100 ppm)  Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated electro-chemical type sensor expected life 5-7 years

Carbon Monoxide – CO – Model 5502-250  (0-250 ppm) Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated electro-chemical type sensor expected life 5-7 years

Carbon Monoxide Sensor -H2 Nil – Model 5502 Replacement Module with reduced  Hydrogen response  0-100 ppm

Chlorine – CL2 – Model 5517  Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated electro-chemical sensor expected life 1-3 years

HCFCs – Model 5513 Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated semi-conductor type sensor expected life 3-5 years for detection of R22, R401A, R402A, R408A, R502

HFCs – Model 5520, Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated semi-conductor type sensor expected life 3-5 years for detection of R134A, R404A, R10A, R507

Hydrogen - H2Hydrogen – H2  – Model 5508, Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated catylitic bead type sensor built-in poison filter expected life 7 years

mode 5525Humidity Sensor Replacement Module – Model 5525, 0-100 percent relative humidity plug-in replacement sensor module for use in Opera 5000 or 6000 controller factory calibrated sensor type expected life

Hydrogen Sulfide – H20-50 ppm – Model 5516, Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated electro-chemical sensor expected life

Methane – CH4  Model 5505, Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated catylitic bead type sensor expected life 5-7 years built in poison filter

Nitrogen Dioxide – NO2 – Model 5514, 0-10 ppm Replacement sensor module for Opera gas detectors series 5000 and 6000 expected life 1-3 years (will vary with enviornmental conditions) electro-chemical type sensor

Organic Vapors – VOC – Model 5501, Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated detects a wide range of organic vapors;

  • Ethylene glycol (C4H4(OH2)
  • Ethanol (C2H5OH2)
  • Iso-propyl Alcohol (C3H7OH)
  • Methanol (CH3OH)

expected life 3-5 years catylitic semi-conductor type sensor

Oxygen Leak- O2 Model 5522, for alarms on rising levels of oxygen (for dropping levels see model 5523) Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated expected life 2 years fuel cell type sensor

Propane – C3H8 – 0-50% LEL – Model 5506, Replacement sensor module for Opera gas detectors series 5000 and 6000 factory calibrated catalytic bead type sensor expected life 5-7 years built in poison filter

REQUEST A QUOTE